Effect of the humidification device on the work of breathing during noninvasive ventilation

145Citations
Citations of this article
94Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Objective: Heat and moisture exchangers (HME) increase circuitry deadspace compared to heated humidifiers (HH). This study compared the effect of HH and HME during noninvasive ventilation (NIV) on arterial blood gases and patient's effort assessed by respiratory muscles pressure-time product and by work of breathing (WOB). Design and setting: Randomized cross-over study in a medical intensive care unit. Patients: Nine patients receiving NIV for moderate to severe acute hypercapnic respiratory failure. Measurements: HME was randomly compared to HH during periods of 20 min. Each device was studied without (ZEEP) and with a PEEP of 5 cmH2O. At the end of each period arterial blood gases, ventilatory parameters, oesophageal and gastric pressures were recorded and indexes of patient's effort calculated. Results: Minute ventilation was significantly higher with HME than with HH (ZEEP: 15.8±3.7 vs. 12.8±3.6 l/min) despite a similar PaCO2 (60±16 vs. 57±16 mmHg). HME was associated with a greater increase in WOB (ZEEP: 15.5±7.7 vs. 8.4±4.5 J/min and PEEP: 11.3±5.7 vs. 7.3±3.8 J/min) and indexes of patient effort. NIV with HME failed to decrease WOB compared to baseline. Addition of PEEP reduced the level of effort, but similar differences between HME and HH were observed. Conclusions: In patients receiving NIV for moderate to severe acute hypercapnic respiratory failure, the use of HME lessens the efficacy of NIV in reducing effort compared to HH.

References Powered by Scopus

Noninvasive ventilation for acute exacerbations of chronic obstructive pulmonary disease

1808Citations
N/AReaders
Get full text

Early use of non-invasive ventilation for acute exacerbations of chronic obstructive pulmonary disease on general respiratory wards: A multicentre randomised controlled trial

1058Citations
N/AReaders
Get full text

Noninvasive ventilation

974Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Non-invasive ventilation in acute respiratory failure

636Citations
N/AReaders
Get full text

Oxygen delivery through high-flow nasal cannulae increase end-expiratory lung volume and reduce respiratory rate in post-cardiac surgical patients

421Citations
N/AReaders
Get full text

Patient-ventilator asynchrony during non-invasive ventilation for acute respiratory failure: A multicenter study

300Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Lellouche, F., Maggiore, S. M., Deye, N., Taillé, S., Pigeot, J., Harf, A., & Brochard, L. (2002). Effect of the humidification device on the work of breathing during noninvasive ventilation. Intensive Care Medicine, 28(11), 1582–1589. https://doi.org/10.1007/s00134-002-1518-9

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 25

39%

Researcher 22

34%

Professor / Associate Prof. 16

25%

Lecturer / Post doc 1

2%

Readers' Discipline

Tooltip

Medicine and Dentistry 54

81%

Nursing and Health Professions 5

7%

Engineering 4

6%

Agricultural and Biological Sciences 4

6%

Save time finding and organizing research with Mendeley

Sign up for free