Concurrent use of the Pipeline Embolization Device and coils for intracranial aneurysms: Technique, safety, and efficacy

53Citations
Citations of this article
36Readers
Mendeley users who have this article in their library.

Abstract

OBJECT: The use of the Pipeline Embolization Device (PED) as a sole endovascular modality has been described for the treatment of brain aneurysms. The benefit of using coils concurrently with a limited number of PEDs is not well documented. The authors describe their experience with this technique as well as their midterm clinical and angiographic results. METHODS:This is a retrospective review of patients treated between 2011 and 2014. The authors placed a minimal number of PEDs with the addition of coils using a "jailed" microcatheter technique. A partially dense coil mass was obtained. Immediate and midterm clinical and angiographic results are reviewed. RESULTS: The authors treated 27 patients harboring 28 aneurysms using this technique. The mean aneurysm size was 11.9 mm, and the mean neck size was 5.4 mm. A mean of 1.48 PEDs were placed per patient, and a mean of 1.33 PEDs per aneurysm were placed. The Raymond score immediately after PED placement was 2 or 3 in 82.1% of the patients. There were no intraprocedural or postprocedural complications. All PEDs were successfully deployed. No clinical or technical adverse effects related to the coil mass were observed. There were no clinical or radiographic signs of ischemia in this group. At follow-up imaging, complete aneurysm occlusion was demonstrated on the first MR angiogram (3-5 months) in all patients who reached this milestone. Follow-up digital subtraction angiography (5-13 months) confirmed complete occlusion in all patients who reached this milestone. All patients maintained their baseline clinical status. CONCLUSIONS:The deployment of PEDs with concurrent partially dense coiling is safe and efficacious. This technique achieved early complete occlusion and endovascular reconstruction of the parent vessel, without inducing mass effect. Favorable midterm clinical results were observed in all patients.

References Powered by Scopus

Long-term angiographic recurrences after selective endovascular treatment of aneurysms with detachable coils

1350Citations
N/AReaders
Get full text

Pipeline for uncoilable or failed aneurysms: Results from a multicenter clinical trial

913Citations
N/AReaders
Get full text

Curative endovascular reconstruction of cerebral aneurysms with the pipeline embolization device: The Buenos Aires experience

719Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Predictors of cerebral aneurysm persistence and occlusion after flow diversion: A single-institution series of 445 cases with angiographic follow-up

120Citations
N/AReaders
Get full text

Flow Diversion for Intracranial Aneurysm Treatment: Trials Involving Flow Diverters and Long-Term Outcomes

73Citations
N/AReaders
Get full text

Flow diversion with the pipeline embolization device for patients with intracranial aneurysms and antiplatelet therapy: A systematic literature review

64Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Nossek, E., Chalif, D. J., Chakraborty, S., Lombardo, K., Black, K. S., & Setton, A. (2015). Concurrent use of the Pipeline Embolization Device and coils for intracranial aneurysms: Technique, safety, and efficacy. Journal of Neurosurgery, 122(4), 904–911. https://doi.org/10.3171/2014.12.JNS141259

Readers over time

‘15‘16‘17‘18‘19‘20‘21‘22‘23‘2402468

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 13

65%

Researcher 4

20%

Professor / Associate Prof. 2

10%

Lecturer / Post doc 1

5%

Readers' Discipline

Tooltip

Medicine and Dentistry 18

82%

Nursing and Health Professions 2

9%

Computer Science 1

5%

Neuroscience 1

5%

Save time finding and organizing research with Mendeley

Sign up for free
0