Validation of the Aktiia blood pressure cuff for clinical use according to the ANSI/AAMI/ISO 81060-2:2013 protocol

9Citations
Citations of this article
20Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Objective Assess the accuracy and precision of the Aktiia initialization oscillometric upper-arm cuff device (Aktiia SA, Neuchâtel, Switzerland) for home blood pressure (BP) monitoring in the general population according to the American National Standards Institute / Association for the Advancement of Medical Instrumentation/International Organization for Standardization (ANSI/AAMI/ISO) 81060-2:2013 standard. Methods Three trained observers validated BP measurements performed using the Aktiia cuff versus BP measurements performed using a standard mercury sphygmomanometer. Two ISO 81060-2 criteria were used to validate the Aktiia cuff. Criterion 1 evaluated, for both SBP and DBP, whether the mean error between BP readings performed by the Aktiia cuff and auscultation was ≤±5 mmHg, and whether the SD of the error was ≤8 mmHg. Criterion 2 assessed whether, for the SBP and DBP of each individual subject, the SD of the averaged paired determinations per subject of the Aktiia cuff and of the auscultation met the criteria listed in the table of Averaged Subject Data Acceptance. Results Mean differences between the Aktiia cuff and the standard mercury sphygmomanometer (criterion 1) were 1.3 ± 7.11 mmHg for SBP and -0.2 ± 5.46 mmHg for DBP. The SD of the averaged paired differences per subject (criterion 2) was 6.55 mmHg for SBP and 5.15 mmHg for DBP. Conclusion Aktiia initialization cuff complies with the requirements of the ANSI/AAMI/ISO guidelines and can be safely recommended for BP measurements in the adult population.

References Powered by Scopus

2017 ACC/AHA/AAPA/ABC/ACPM/AGS/APhA/ASH/ASPC/NMA/PCNA Guideline for the Prevention, Detection, Evaluation, and Management of High Blood Pressure in Adults: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines

3903Citations
N/AReaders
Get full text

2020 International Society of Hypertension Global Hypertension Practice Guidelines

2339Citations
N/AReaders
Get full text

2018 ESC/ESHGuidelines for themanagement of arterial hypertension

2269Citations
N/AReaders
Get full text

Cited by Powered by Scopus

The Promise and Illusion of Continuous, Cuffless Blood Pressure Monitoring

4Citations
N/AReaders
Get full text

History and evolution of blood pressure measurement

3Citations
N/AReaders
Get full text

Transforming blood pressure control in primary care through a novel remote decision support strategy based on wearable blood pressure monitoring: The NEXTGEN-BP randomized trial protocol

3Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Alexandre, J., Tan, K., Almeida, T. P., Sola, J., Alpert, B. S., & Shah, J. (2023). Validation of the Aktiia blood pressure cuff for clinical use according to the ANSI/AAMI/ISO 81060-2:2013 protocol. Blood Pressure Monitoring, 28(2), 109–112. https://doi.org/10.1097/MBP.0000000000000639

Readers' Seniority

Tooltip

Researcher 3

50%

PhD / Post grad / Masters / Doc 2

33%

Professor / Associate Prof. 1

17%

Readers' Discipline

Tooltip

Medicine and Dentistry 5

56%

Engineering 3

33%

Sports and Recreations 1

11%

Save time finding and organizing research with Mendeley

Sign up for free