A rapid portable technique for estimating macular pigment optical density (MPOD) in large populations is described. The new instrument utilises a novel method for setting flicker thresholds which is undemanding for naïve and elderly observers and easily operated by a non-technical person. The method has good repeatability (r = 0.97) and the data are comparable with an optical method based on retinal reflectometry (r = 0.78). MPOD spatial profiles are presented for seven normal observers and these are well described (r = 0.99) by a decaying exponential function consistent with previous reports. MPOD values are presented from 5581 (2435 females and 3146 males) individuals measured in 48 optometric practices. The mean MPOD of this population was 0.33 (S.D. ± 0.187) which is similar to previous large scale studies of MP. © 2009 The College of Optometrists.

References Powered by Scopus

The role of oxidative stress in the pathogenesis of age-related macular degeneration

1766Citations
N/AReaders
Get full text

Dietary Carotenoids, Vitamins A, C, and E, and Advanced Age-Related Macular Degeneration

1355Citations
N/AReaders
Get full text

Lutein, zeaxanthin, and the macular pigment

720Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Measuring macular pigment optical density in vivo: A review of techniques

114Citations
N/AReaders
Get full text

Lutein supplementation over a one-year period in early AMD might have a mild beneficial effect on visual acuity: The CLEAR study

97Citations
N/AReaders
Get full text

Randomized, double-blind, placebo-controlled study of zeaxanthin and visual function in patients with atrophic age-related macular degeneration: The Zeaxanthin and Visual Function Study (ZVF) FDA IND #78, 973

86Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Van Der Veen, R. L. P., Berendschot, T. T. J. M., Hendrikse, F., Carden, D., Makridaki, M., & Murray, I. J. (2009). A new desktop instrument for measuring macular pigment optical density based on a novel technique for setting flicker thresholds. Ophthalmic and Physiological Optics, 29(2), 127–137. https://doi.org/10.1111/j.1475-1313.2008.00618.x

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 24

56%

Researcher 14

33%

Lecturer / Post doc 3

7%

Professor / Associate Prof. 2

5%

Readers' Discipline

Tooltip

Medicine and Dentistry 20

63%

Nursing and Health Professions 5

16%

Materials Science 4

13%

Neuroscience 3

9%

Save time finding and organizing research with Mendeley

Sign up for free