A broad scope knowledge based model for optimization of VMAT in esophageal cancer: Validation and assessment of plan quality among different treatment centers

92Citations
Citations of this article
60Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: To evaluate the performance of a broad scope model-based optimisation process for volumetric modulated arc therapy applied to esophageal cancer. Methods and materials: A set of 70 previously treated patients in two different institutions, were selected to train a model for the prediction of dose-volume constraints. The model was built with a broad-scope purpose, aiming to be effective for different dose prescriptions and tumour localisations. It was validated on three groups of patients from the same institution and from another clinic not providing patients for the training phase. Comparison of the automated plans was done against reference cases given by the clinically accepted plans. Results: Quantitative improvements (statistically significant for the majority of the analysed dose-volume parameters) were observed between the benchmark and the test plans. Of 624 dose-volume objectives assessed for plan evaluation, in 21 cases (3.3 %) the reference plans failed to respect the constraints while the model-based plans succeeded. Only in 3 cases (<0.5 %) the reference plans passed the criteria while the model-based failed. In 5.3 % of the cases both groups of plans failed and in the remaining cases both passed the tests. Conclusions: Plans were optimised using a broad scope knowledge-based model to determine the dose-volume constraints. The results showed dosimetric improvements when compared to the benchmark data. Particularly the plans optimised for patients from the third centre, not participating to the training, resulted in superior quality. The data suggests that the new engine is reliable and could encourage its application to clinical practice.

References Powered by Scopus

Predicting dose-volume histograms for organs-at-risk in IMRT planning

338Citations
N/AReaders
Get full text

A planning quality evaluation tool for prostate adaptive IMRT based on machine learning

311Citations
N/AReaders
Get full text

Patient geometry-driven information retrieval for IMRT treatment plan quality control

287Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Automation in intensity modulated radiotherapy treatment planning-a review of recent innovations

191Citations
N/AReaders
Get full text

Knowledge-based planning for intensity-modulated radiation therapy: A review of data-driven approaches

182Citations
N/AReaders
Get full text

A Review on Application of Deep Learning Algorithms in External Beam Radiotherapy Automated Treatment Planning

103Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Fogliata, A., Nicolini, G., Clivio, A., Vanetti, E., Laksar, S., Tozzi, A., … Cozzi, L. (2015). A broad scope knowledge based model for optimization of VMAT in esophageal cancer: Validation and assessment of plan quality among different treatment centers. Radiation Oncology, 10(1). https://doi.org/10.1186/s13014-015-0530-5

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 32

73%

Professor / Associate Prof. 6

14%

Researcher 6

14%

Readers' Discipline

Tooltip

Physics and Astronomy 16

48%

Medicine and Dentistry 11

33%

Engineering 5

15%

Decision Sciences 1

3%

Save time finding and organizing research with Mendeley

Sign up for free