Performance of intermittently scanned continuous glucose monitoring systems in people with type 1 diabetes: A pooled analysis

14Citations
Citations of this article
22Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Aims: To conduct a pooled analysis to assess the performance of intermittently scanned continuous glucose monitoring (isCGM) in association with the rate of change in sensor glucose in a cohort of children, adolescents, and adults with type 1 diabetes. Material and Methods: In this pooled analysis, isCGM system accuracy was assessed depending on the rate of change in sensor glucose. Clinical studies that have been investigating isCGM accuracy against blood glucose, accompanied with collection time points were included in this analysis. isCGM performance was assessed by means of median absolute relative difference (MedARD), Parkes error grid (PEG) and Bland-Altman plot analyses. Results: Twelve studies comprising 311 participants were included, with a total of 15 837 paired measurements. The overall MedARD (interquartile range) was 12.7% (5.9-23.5) and MedARD differed significantly based on the rate of change in glucose (P < 0.001). An absolute difference of −22 mg/dL (−1.2 mmol/L) (95% limits of agreement [LoA] 60 mg/dL (3.3 mmol/L), −103 mg/dL (−5.7 mmol/L)) was found when glucose was rapidly increasing (isCGM glucose minus reference blood glucose), while a −32 mg/dL (1.8 mmol/L) (95% LoA 116 mg/dL (6.4 mmol/L), −51 mg/dL (−2.8 mmol/L)) absolute difference was observed in periods of rapidly decreasing glucose. Conclusions: The performance of isCGM was good when compared to reference blood glucose measurements. The rate of change in glucose for both increasing and decreasing glucose levels diminished isCGM performance, showing lower accuracy during high rates of glucose change.

References Powered by Scopus

Clinical targets for continuous glucose monitoring data interpretation: Recommendations from the international consensus on time in range

2624Citations
N/AReaders
Get full text

Accuracy and longevity of an implantable continuous glucose sensor in the PRECISE study: A 180-day, prospective, multicenter, pivotal trial

139Citations
N/AReaders
Get full text

Glucose management for exercise using continuous glucose monitoring (CGM) and intermittently scanned CGM (isCGM) systems in type 1 diabetes: position statement of the European Association for the Study of Diabetes (EASD) and of the International Society for Pediatric and Adolescent Diabetes (ISPAD) endorsed by JDRF and supported by the American Diabetes Association (ADA)

138Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Association of Blood Glucose Level and Glycemic Variability With Mortality in Sepsis Patients During ICU Hospitalization

45Citations
N/AReaders
Get full text

Use of Continuous Glucose Monitors by People Without Diabetes: An Idea Whose Time Has Come?

30Citations
N/AReaders
Get full text

Clinical Performance Evaluation of Continuous Glucose Monitoring Systems: A Scoping Review and Recommendations for Reporting

28Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Moser, O., Sternad, C., Eckstein, M. L., Szadkowska, A., Michalak, A., Mader, J. K., … Sourij, H. (2022). Performance of intermittently scanned continuous glucose monitoring systems in people with type 1 diabetes: A pooled analysis. Diabetes, Obesity and Metabolism, 24(3), 522–529. https://doi.org/10.1111/dom.14609

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 5

38%

Professor / Associate Prof. 4

31%

Researcher 3

23%

Lecturer / Post doc 1

8%

Readers' Discipline

Tooltip

Sports and Recreations 6

50%

Medicine and Dentistry 3

25%

Nursing and Health Professions 2

17%

Pharmacology, Toxicology and Pharmaceut... 1

8%

Save time finding and organizing research with Mendeley

Sign up for free