Impact of keratinized mucosa on implant-health related parameters: A 10-year prospective re-analysis study

9Citations
Citations of this article
27Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Aim: To investigate whether the lack of keratinized mucosa (KM) affects peri-implant health after 10 years of loading. Materials and Methods: Data from 74 patients with 148 implants from two randomized controlled studies comparing different implant systems were included and analyzed. Clinical parameters including bleeding on probing (BOP), probing depth (PD), plaque index, marginal bone loss (MBL), and KM width (KMW) at buccal sites were collected at baseline (time of the final prosthesis insertion), 5-year and 10 years postloading. Multivariable logistic and linear regression models by means of a generalized estimated equation (GEE) were used to evaluate the influence of buccal KM on peri-implant clinical parameters; BOP, MBL, PD, and adjusted for implant type (one-piece or two-piece) and compliance. Results: A total of 35 (24.8%) implants were healthy, 67 (47.5%) had mucositis and 39 (27.6%) were affected by peri-implantitis. In absence of buccal KM (KM = 0 mm), 75% of the implants exhibited mucositis, while in the presence of KM (KMW >0 mm) 41.2% exhibited mucositis. Regarding peri-implantitis, the corresponding percentages were 20% (KM = 0 mm) and 26.7% (KM >0 mm). Unadjusted logistic regression showed that the presence of buccal KM tended to reduce the odds of showing BOP at buccal sites (OR: 0.28 [95% CI, 0.07 to 1.09], p = 0.06). The adjusted logistic regression model revealed that having buccal KM (OR: 0.21 [95% CI, 0.05 to 0.85], p = 0.02) and using two-piece implants (OR: 0.34 [95% CI, 0.15 to 0.75], p = 0.008) significantly reduced the odds of showing BOP. Adjusted linear regression by means of GEE showed that KM and two-piece implants were associated with reduced MBL and MBL changes (p < 0.05). Conclusion: The lack of buccal KM appears to be linked with peri-implant parameters such as BOP and MBL, but the association is weak. The design of one-piece implants may account for their increased odds of exhibiting BOP.

References Powered by Scopus

Cited by Powered by Scopus

This article is free to access.

Get full text

Fixed Full-Arch Maxillary Prostheses Supported by Four Versus Six Implants: 5-Year Results of a Multicenter Randomized Clinical Trial

1Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Mancini, L., Strauss, F. J., Lim, H. C., Tavelli, L., Jung, R. E., Naenni, N., & Thoma, D. S. (2024). Impact of keratinized mucosa on implant-health related parameters: A 10-year prospective re-analysis study. Clinical Implant Dentistry and Related Research, 26(3), 554–563. https://doi.org/10.1111/cid.13314

Readers over time

‘24‘2506121824

Readers' Seniority

Tooltip

Professor / Associate Prof. 4

57%

PhD / Post grad / Masters / Doc 3

43%

Readers' Discipline

Tooltip

Medicine and Dentistry 5

42%

Nursing and Health Professions 4

33%

Biochemistry, Genetics and Molecular Bi... 2

17%

Chemistry 1

8%

Save time finding and organizing research with Mendeley

Sign up for free
0