A feasibility analysis of replacing the standard ammonia refrigeration device with the cascade NH3/CO2 refrigeration device in the food industry

6Citations
Citations of this article
20Readers
Mendeley users who have this article in their library.

Abstract

The thermodynamic analysis demonstrates the feasibility of replacing the standard ammonia refrigeration device with the cascade NH3/CO2 refrigeration device in the food industry. The main reason for replacement is to reduce the total amount of ammonia in spaces like deep-freezing chambers, daily chambers, working rooms, and technical passageways. An ammonia-contaminated area is hazardous to human health and the safety of food products. Therefore, the preferred reduced amount of ammonia is accumulated in the central refrigeration engine room, where the cascade NH3/CO2 device is installed as well. Furthermore, the analysis discusses and compares two Carnot's refrigeration cycles, one for the standard ammonia device and the other for the cascade NH3/CO2 device. Both cycles are processes with two-stage compression and two-stage throttling. The thermodynamic analysis demonstrates that the selected refrigeration cycle is the most cost-effective process because it provides the best numerical values for the total coefficient of performance with respect to the observed refrigeration cycle. The chief analyzed influential parameters of the cascade device are: total refrigeration load, total compressor power, mean temperature of the heat exchanger, evaporating and condensing temperature of the low-temperature part.

References Powered by Scopus

Revival of carbon dioxide as a refrigerant

645Citations
N/AReaders
Get full text

The construction of global warming and the politics of science

601Citations
N/AReaders
Get full text

The importance of the Montreal Protocol in protecting climate

423Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Energy and exergy analysis of NH<inf>3</inf>/CO<inf>2</inf> cascade refrigeration system with subcooling in the low-temperature cycle based on an auxiliary loop of NH<inf>3</inf> refrigerants

24Citations
N/AReaders
Get full text

Performance evaluation of NH<inf>3</inf>/CO<inf>2</inf> cascade refrigeration system with ejector subcooling for low-temperature cycle

24Citations
N/AReaders
Get full text

Performance analysis of a CO<inf>2</inf>/NH<inf>3</inf> cascade refrigeration system with subcooling for low temperature freezing applications

10Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Jankovich, D., & Osman, K. (2015). A feasibility analysis of replacing the standard ammonia refrigeration device with the cascade NH3/CO2 refrigeration device in the food industry. Thermal Science, 19(5), 1821–1833. https://doi.org/10.2298/TSCI130611097J

Readers' Seniority

Tooltip

Researcher 4

67%

Professor / Associate Prof. 1

17%

PhD / Post grad / Masters / Doc 1

17%

Readers' Discipline

Tooltip

Engineering 5

56%

Energy 2

22%

Design 1

11%

Physics and Astronomy 1

11%

Save time finding and organizing research with Mendeley

Sign up for free