Reliability and validity of bilateral ankle accelerometer algorithms for activity recognition and walking speed after stroke

95Citations
Citations of this article
348Readers
Mendeley users who have this article in their library.

Abstract

Background and Purpose-Outcome measures of mobility for large stroke trials are limited to timed walks for short distances in a laboratory, step counters and ordinal scales of disability and quality of life. Continuous monitoring and outcome measurements of the type and quantity of activity in the community would provide direct data about daily performance, including compliance with exercise and skills practice during routine care and clinical trials. Methods-Twelve adults with impaired ambulation from hemiparetic stroke and 6 healthy controls wore triaxial accelerometers on their ankles. Walking speed for repeated outdoor walks was determined by machine-learning algorithms and compared to a stopwatch calculation of speed for distances not known to the algorithm. The reliability of recognizing walking, exercise, and cycling by the algorithms was compared to activity logs. Results-A high correlation was found between stopwatch-measured outdoor walking speed and algorithm-calculated speed (Pearson coefficient, 0.98; P=0.001) and for repeated measures of algorithm-derived walking speed (P=0.01). Bouts of walking >5 steps, variations in walking speed, cycling, stair climbing, and leg exercises were correctly identified during a day in the community. Compared to healthy subjects, those with stroke were, as expected, more sedentary and slower, and their gait revealed high paretic-to-unaffected leg swing ratios. Conclusions-Test-retest reliability and concurrent and construct validity are high for activity pattern-recognition Bayesian algorithms developed from inertial sensors. This ratio scale data can provide real-world monitoring and outcome measurements of lower extremity activities and walking speed for stroke and rehabilitation studies. © 2011 American Heart Association, Inc.

References Powered by Scopus

On the Optimality of the Simple Bayesian Classifier under Zero-One Loss

2540Citations
N/AReaders
Get full text

Cardiovascular risk prediction: Basic concepts, current status, and future directions

586Citations
N/AReaders
Get full text

Multicenter randomized clinical trial evaluating the effectiveness of the Lokomat in subacute stroke

516Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Guidelines for Adult Stroke Rehabilitation and Recovery: A Guideline for Healthcare Professionals from the American Heart Association/American Stroke Association

2152Citations
N/AReaders
Get full text

Window size impact in human activity recognition

524Citations
N/AReaders
Get full text

The promise of mHealth: Daily activity monitoring and outcome assessments by wearable sensors

241Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Dobkin, B. H., Xu, X., Batalin, M., Thomas, S., & Kaiser, W. (2011). Reliability and validity of bilateral ankle accelerometer algorithms for activity recognition and walking speed after stroke. Stroke, 42(8), 2246–2250. https://doi.org/10.1161/STROKEAHA.110.611095

Readers over time

‘11‘12‘13‘14‘15‘16‘17‘18‘19‘20‘21‘22‘23‘24‘25020406080

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 146

66%

Researcher 40

18%

Professor / Associate Prof. 29

13%

Lecturer / Post doc 5

2%

Readers' Discipline

Tooltip

Medicine and Dentistry 60

33%

Engineering 49

27%

Nursing and Health Professions 47

26%

Neuroscience 24

13%

Save time finding and organizing research with Mendeley

Sign up for free
0