Independent diagnostic accuracy of flow cytometry obtained from fine-needle aspirates a 10-year experience with 451 cases

32Citations
Citations of this article
32Readers
Mendeley users who have this article in their library.

Abstract

Although the topic is somewhat contentious, fine-needle aspiration (FNA) is frequently used in conjunction with flow cytometry (FC) to evaluate lymphoid proliferations. Despite the fact that the FNA and FC are often analyzed independently, no previous large-scale study has independently analyzed FC of FNA specimens. FC reports of 511 FNAs were retrospectively reviewed and FC diagnoses categorized as monoclonal, atypical, normal/reactive, or insufficient cellularity (3.9%). Abnormal immunophenotype was considered a positive test result. "Gold standard" diagnoses were established by histologic examination, treatment based on FNA, or clinical features. In 92.2% (451/489), there was adequate follow-up. The diagnostic accuracy of FC was 88.4%, sensitivity was 85.8%, and specificity was 92.9%. In addition, FC accuracy for classes of non-Hodgkin lymphoma was assessed. We conclude that FC is an independently accurate ancillary test in the evaluation of FNA. However, the presence of false-negative and falsepositive cases supports the common practice of correlating FC with cytomorphologic findings even if performed independently. © American Society for Clinical Pathology.

References Powered by Scopus

A revised European-American classification of lymphoid neoplasms: A proposal from the International Lymphoma Study Group

6289Citations
N/AReaders
Get full text

World health organization classification of neoplastic diseases of the hematopoietic and lymphoid tissues: Report of the clinical advisory committee meeting - Airlie house, Virginia, November 1997

2557Citations
N/AReaders
Get full text

Utility of fine-needle aspiration as a diagnostic technique in lymphoma

241Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Notch reporter activity in breast cancer cell lines identifies a subset of cells with stem cell activity

109Citations
N/AReaders
Get full text

Design and clinical validation of a point-of-care device for the diagnosis of lymphoma via contrast-enhanced microholography and machine learning

55Citations
N/AReaders
Get full text

Tissue flow cytometry immunophenotyping in the diagnosis and classification of non-Hodgkin's lymphomas: A retrospective evaluation of 1,792 cases

38Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Savage, E. C., Vanderheyden, A. D., Bell, A. M., Syrbu, S. I., & Jensen, C. S. (2011). Independent diagnostic accuracy of flow cytometry obtained from fine-needle aspirates a 10-year experience with 451 cases. American Journal of Clinical Pathology, 135(2), 304–309. https://doi.org/10.1309/AJCPHY69XVJGULKO

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 10

56%

Professor / Associate Prof. 5

28%

Researcher 3

17%

Readers' Discipline

Tooltip

Medicine and Dentistry 13

76%

Immunology and Microbiology 2

12%

Chemical Engineering 1

6%

Materials Science 1

6%

Save time finding and organizing research with Mendeley

Sign up for free